| Buttons (through screw-terminal connectors) |
5 pre-programmed 15 programmable zone/function buttons 3 supervised programmable optional emergency buttons 2 connections for each button; 23 buttons share 6 common VCCs (3V3 – DC) Each button has short circuit protection |
| LEDs connected to buttons (through screw-terminal connectors) |
This kit supports open drain outputs with max. 5 mA per output. Using the internal supply, a maximum of 100 mA can be sourced for all outputs. The kit also provides an external power supply for lighting LEDs of external normal buttons. 2 connections (VCC & open collector) are available for each LED connected to a button. In total, 38 LEDs share 10 common MIX_PWR_LED. These LEDs are supplied with 5 V DC using the internal power supply. The connected LEDs are supplied with 24 V DC using the external power supply. Each LED circuit has short-circuit protection. |
| Power LED (through screw-terminal connectors) |
Driven by MIX_PWR_LED (5 V DC or 24 V DC) 2 connections (VCC & open collector) |
| Fault LED (through screw-terminal connectors) |
Driven by MIX_PWR_LED (5 V DC or 24 V DC) 2 connections (VCC & open collector) |
| Alarm LED (through screw-terminal connectors) |
Driven by MIX_PWR_LED (5 V DC or 24 V DC) 2 connections (VCC & open collector) |
| Included LCD display kit |
A flat ribbon cable connects the display to the call station kit mainboard. The ribbon cable length is +/- 300 mm |
| Others (through screw-terminal connectors) |
1 audio source (line in) 1 supervised microphone input (eg. LBB9081) capsule and PTT button connection (input & VCC) with short-circuit protection. 1 loudspeaker connection, 1 additional +24 V DC power supply |
| External connectors |
1 call station bus connector (control data + audio + power supply, RJ-45) 1 EXT connector (RJ-12, e.g. for call station extension) |
| Main power supply |
|
| Nominal voltage |
24 V DC (-10%/+30%) |
| Maximum voltage range |
15–58 V DC |
| Nominal current consumption for main power supply |
< 100 mA |
| Maximum supply current |
|
| External power supply for lighting, without extensions |
< 80 mA/24 V < 110 mA/18 V |
| Internal power supply for lighting, without extensions |
< 150 mA/24 V < 200 mA/18 V |
| CAN interface |
10, 20, or 62.5 kbit/s |
| Maximum mic input level |
-21 dBu |
| Maximum line input level |
+4 dBu |
| NF output |
Balanced |
| Nominal level |
+6 dBu |
| Maximum level |
+12 dBu |
| Frequency response |
200–16,000 Hz, +0/-3 dB |
| Signal-to-noise ratio (Mic and Line input, NF output) |
≥ 60 dB |
| Buttons |
|
| Nominal voltage |
3.3 V DC |
| Max current |
100 mA |
| PTT input switch |
|
| Nominal voltage |
3.3 V DC |
| Max current |
100 mA |
| LEDs |
|
| Nominal drive current |
5 mA for each LED |
| Maximum drive current |
20 mA for each LED |
| Nominal drive voltage |
5 V by internal power supply for 5-V point lighting LEDs 24 V by external power supply for 24-V ring lighting LEDs |
| Additional power supply for industrial buttons backlight |
|
| Nominal voltage |
24 V DC (-10/+30%) |
| Nominal current consumption |
< 300 mA |
| Maximum supply current |
< 500 mA at 24 V |
| External speaker |
|
| Nominal resistance |
8 Ω |
| Power rating |
1.5 W |
| Maximum power |
2 W |
| Nominal operating voltage |
3.5 V |
| Normal microphone (e.g. LBB 9081 reference) |
|
| Sensitivity |
3.1 mV/Pa ±4 dB |
| Frequency response |
280–14000 Hz |
| Rated output impedance |
500 Ω |
| Polar pattern |
Omnidirectional |
| Switch |
On/off with remote control contact |